A compressor is a mechanical device that increases the pressure of a gas by reducing its volume.An air compressor is a specific type of gas compressor.. Compressors are similar to pumps: both increase the pressure on a fluid and both can transport the fluid through a pipe.As gases are compressible, the compressor also reduces the volume of a gas. Liquids are …
Get DetailsA heat exchanger is a system used to transfer heat between two or more fluids.Heat exchangers are used in both cooling and heating processes. The fluids may be separated by a solid wall to prevent mixing or they may be in direct contact. They are widely used in space heating, refrigeration, air conditioning, power stations, chemical plants, petrochemical plants, petroleum …
Get DetailsA powerful motor provides twice the flow rate of other extended-life circulation pumps. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Magnets turn the impeller to eliminate seal wear and leakage for a long service life. These pumps are often used with electroplating and photographic solutions.
Get DetailsAug 15, 2016 Data from the 2012 Commercial Buildings Energy Consumption Survey (CBECS) shows that the United States consumes 6,963 trillion Btu of energy generated for commercial buildings. Figure 1 shows that 44% of commercial building energy use is for HVAC and refrigeration. National survey data shows approximately 50% of the HVAC energy is used for …
Get DetailsConsider a thermal storage system when designing your chiller plant. With a thermal storage system, the idea is to run chiller equipment during off-peak periods and store cooled water or ice, then draw on this cooling during the peak times of the day.
Get DetailsDesigned to Perform. Built to Last. For over 65 years, Mokon has set the standard for high quality heating and cooling process temperature control systems. We provide accurate and reliable temperature control ranging from -20 F to 700 F (-29 C to 371 C).
Get DetailsDirectional control valves and manifolds direct air to pneumatic actuators, vacuum equipment and as pilot air for large-scale industrial process valves making them fundamental to industrial automation applications. SMC pneumatic valves can be …
Get DetailsIn industrial applications, they have to transport fluids from one point to another through pipes or open ducts which require the determination of pressure drops in the system, selection of a proper type of pump or compressor, power required for pumping or compression, and measurement of …
Get DetailsNov 16, 2017 IoT can provide the tools for such optimization by providing real-time monitoring of power consumption from each part of the chiller plant, supply/return temperatures from the chiller and cooling tower, water flow rates from the condenser water loop, etc. IoT has found practical application in HVAC to facilitate true optimization.
Get DetailsSynchronous Electronic Motors: Fan coil units are outfitted with electrically efficient variable speed motors to modulate air flow rates with changing heating and cooling loads. Fans that operate at lower speeds when the heating and cooling loads are low use far less energy and often have the added benefit of being a quitter.
Get DetailsThe ALVTN-Mass mass flowmeter measures and computes mass flow rates of steam to control heat for boiling the wort, in 500 bbl (15,000-gallon) kettles. The boiling operation continues for 90 minutes, evaporating about 5 to 10% of the solution.
Get DetailsThe chiller controller monitors the operating conditions and uses a combination of inlet guide vanes and speed control. Compressor speed is typically only lowered to about 60% of the design speed. Since VFDs introduce drive losses, the chiller will not be as efficient at full load (speed) with a VFD as with a standard starter.
Get DetailsThe difficulty is that the chiller and control system must be designed for variable flow. The chiller has a minimum flow rate so the piping design has to allow for enough flow during all operating conditions to meet the chiller minimum flow rate. Using two-way valves is the main building block for a variable flow system.
Get Detailsthe tubes. This particular technical solution allows the i-Chiller to operate with high flow rates and reduced pressure drops, ensuring a high level of reliability in heavy industrial applications and also with liquids containing impurities. The antifreeze function …
Get DetailsCopyright © 2022 Berlio Machinery Company All rights reserved sitemap